Conductivity
Handheld
Meters
CON 110 CON 11
Conductivity
Range
.. to 19.99 µS/cm ; .. to 199.9 µS/cm ; .. to 1999 µS/cm
.. to 19.99 mS/cm ; .. to 199.9 mS/cm
Resolution 0.05 % Full scale
Accuracy ± 1% Full scale + 1 digit
TDS
Range
.. to 9.99 ppm ; .. to 99.9 ppm ; .. to 999 ppm
.. to 9.99 ppt ; .. to 99.9 ppt (Based on TDS factor 0.50)
Resolution 0.05 % Full scale
Accuracy ± 1% Full scale + 1 digit
Temperature
Range - 10.0 to 110.0
º
C or 14.0 to 230
º
F - 10.0 to 110.0
º
C
Resolution 0.1
º
C /
º
F 0.1
º
C
Accuracy ± 0.5
º
C (± 0.9
º
F) ± 0.5
º
C
TDS Factor 0.40 to 1.00 (Selectable)
Temperature Coecient 0 to 10 % /
º
C (Selectable)
No. of Calibration Points
Automatic : 1 to 4 points (84.0 µS/cm, 1413 µS/cm; 12.88 mS/cm, 111.8 mS/cm)
Manual : 1 to 5 points (User dened standards / 1 per range)
Cell Constant 0.1, 1.0, 10.0 (Selectable)
Normalisation Temperature 20.0 or 25.0
º
C
CyberScan Standard Handheld
Specication Tables
pH
Handheld
Meters
pH 110 pH 11
pH
Range - 2.00 to 16.00 pH
Resolution 0.01 pH
Accuracy ± 0.01 pH
Temperature
Range - 10.0 to 110.0
º
C or 14.0 to 230
º
F - 10.0 to 110.0
º
C
Resolution 0.1
º
C /
º
F 0.1
º
C
Accuracy ± 0.5
º
C (± 0.9
º
F) ± 0.5
º
C
mV (Extended)
Range -1999 to 1999 mV
Resolution 1 mV
Accuracy ± 0.2 mV
mV
Range - 199.9 to + 199.9 mV
Resolution 0.1 mV
Accuracy ± 0.2 mV
No. of Calibration Points 2 to 6 Points (With DIN pH buers) 2 to 5 Points
pH Buer Sets
USA : pH 1.68 / 4.01 / 7.00 / 10.01 / 12.45
NIST : pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45
DIN : pH 1.09 / 3.06 / 4.65 / 6.79 / 9.23 / 12.75
Low Ionic : pH 4.10 / 6.97
USA : pH 1.68 / 4.01 / 7.00 / 10.01 / 12.45
NIST : pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45
Dissolved
Oxygen
Handheld Meter
DO 110
Dissolved Oxygen
Range 0.00 to 19.99 mg/l or ppm
Resolution 0.01 mg/l; 0.01 ppm
Accuracy ± 1.5 % Full scale
% Saturation
Of Oxygen
Range 0.0 to 199.9 %
Resolution 0.1
%
Accuracy ± 1.5 % Full scale
Temperature
Range 0.0 to 50.0
º
C or 32.0 to 122
º
F
Resolution 0.1
º
C /
º
F
Accuracy ± 0.3
º
C / 0.5
º
F
Salinity Correction
Range 0.0 to 50.0 ppt
Resolution 0.1 ppt
Method Automatic correction after manual input
Barometric Pressure
Correction
Range 500 to 1499 mmHg or 66.6 to 199.9 kPA
Resolution 1 mmHg or 0.1 kPA
Method Automatic correction after manual input
No. of Calibration Points 2 points (0 % and 100%)