Strany 1 - Instruction Manual

TechnologyMadeEasy...Instruction Manual αlpha CON 2000 Conductivity/ Total Dissolved Solids Controller / Transmitter 68X216843 Rev 1 01/

Strany 2

Instruction Manual αlpha CON 2000 42.2 Measurement and control system A typical measurement system consists of: • A conductivity process trans

Strany 3

Instruction Manual αlpha CON 2000 52.3 Unit overview Wall mounting version Panel mounting version

Strany 4

Instruction Manual αlpha CON 2000 62.3.1 Display Overview The LC display shows two alpha-numerical fields for parameters and measured values as

Strany 5 - TABLE OF CONTENTS

Instruction Manual αlpha CON 2000 72.3.3 LED indicators Relay indicators If REL key is pressed the LED (A, B or W) indicates to which Rela

Strany 6

Instruction Manual αlpha CON 2000 82.3.5 Menu overview CCD “000” = Check calibration parameters (View only mode) CCD “11” = Calibration mode SC

Strany 7 - 1 INTRODUCTION

Instruction Manual αlpha CON 2000 93 ASSEMBLY AND INSTALLATION 3.1 Mounting the unit Wall mounting version approx. 14 [.55]39 [1.54]Hole

Strany 8 - 1.3 Safety intsructions

Instruction Manual αlpha CON 2000 10Panel mounting version Flat gasket 1mm [.04](to be inserted by customer)Panel cut outUNIT: MM [INCH] Trans

Strany 9 - 2 PRODUCT DESCRIPTION

Instruction Manual αlpha CON 2000 113.2 Connection Diagram Caution: Ensure electrical mains are disconnected before proceeding. Connections fo

Strany 10

Instruction Manual αlpha CON 2000 12 NOTE: a) Switch or circuit breaker shall included in the building installation. b) It shall be in clos

Strany 11 - 2.3 Unit overview

Instruction Manual αlpha CON 2000 13Connections for panel mounting version 1. AC mains live wire **17. 4 Cell / 2 Cell type Conductivity Inp

Strany 13

Instruction Manual αlpha CON 2000 14 NOTE: 1) Switch or circuit breaker shall included in the building installation. 2) It shall be in close

Strany 14 - SCD “22” = Setup mode

Instruction Manual αlpha CON 2000 154 NORMAL OPERATION 4.1 Measurement mode When the transmitter is powered on, the display first shows all

Strany 15 - 3.1 Mounting the unit

Instruction Manual αlpha CON 2000 165 CALIBRATION MODE You can access the Calibration mode directly from the Measurement mode by pressing the

Strany 16 - UNIT: MM [INCH]

Instruction Manual αlpha CON 2000 175.2 Calibration This transmitter features a one-point calibration. Note: The calibration is always carrie

Strany 17 - 3.2 Connection Diagram

Instruction Manual αlpha CON 2000 18 Note: If you entered the Calibration mode from the Setup mode, the transmitter will return to the setup menu

Strany 18

Instruction Manual αlpha CON 2000 19MEASSETUPSETUPSETUPSETUPSETUPSETUPSETUPSETUPSETUPSETUPHOLDHOLDHOLDHOLDHOLDHOLDHOLDHOLDHOLDHOLDµS444444444444°

Strany 19

Instruction Manual αlpha CON 2000 206.2 Temperature compensation (TC) sub-function This sub-function allows you to select the correct temperatu

Strany 20

Instruction Manual αlpha CON 2000 216.3 Setting temperature (Set °C°F) sub-function SETUPSETUPSETUPHOLDHOLDHOLD444ENTSETUPSETUPHOLDHOLD44ENT°C

Strany 21 - 4 NORMAL OPERATION

Instruction Manual αlpha CON 2000 226.4 Control Relay A / Relay B (SP1/SP2) sub-function The SP1 sub-function determines the operating paramete

Strany 22 - 5 CALIBRATION MODE

Instruction Manual αlpha CON 2000 23 5. Setting the on-delay time lag: press the ▲ or ▼ key to enter the on-delay time for set point 1 (set poin

Strany 23 - 5.2 Calibration

Preface This manual serves to explain the use of the αlpha CON 2000 Series. The manual functions in two ways, firstly as a step by step guide to help

Strany 24

Instruction Manual αlpha CON 2000 246.5 Controller (CNTR) sub-function The CNTR sub-function determines the controller’s parameters. SETUPSET

Strany 25 - 6 SETUP MODE

Instruction Manual αlpha CON 2000 251. Select the “CNTR” subfunction, then press the ENT key. 2. Selecting the controller type: press the ▲ or

Strany 26

Instruction Manual αlpha CON 2000 26 − If the proportional controller type is set to pulse frequency control (PFC): 9. Selecting the relay sta

Strany 27

Instruction Manual αlpha CON 2000 276.6 Current Output 1 sub-function In this subfunction you set the current output range of the transmitter f

Strany 28

Instruction Manual αlpha CON 2000 286.7 Current Output 2 sub-function In this sub-function you set the current output range of the transmitter

Strany 29

Instruction Manual αlpha CON 2000 296.8 Wash relay (WASH) sub-function In this sub-function you set the parameters for the wash relay. SETUP

Strany 30

Instruction Manual αlpha CON 2000 30SETUPSETUPSETUPSETUPSETUPSETUPSETUPSETUPHOLDHOLDHOLDHOLDHOLDHOLDHOLDHOLDµSµSµSµSmSmSmS41234567ENTENTENTENTENT

Strany 31

Instruction Manual αlpha CON 2000 316.10 Configuration (CNFG) sub-function In this sub-function you configure the transmitter to suit your req

Strany 32

Instruction Manual αlpha CON 2000 32 6. Selecting the alarm contact type: press the ▲ or ▼ key to select the alarm contact type: − “STDY” = st

Strany 33

Instruction Manual αlpha CON 2000 337 RELAY MODES You can control devices connected to Relay A, Relay B or wash relay via the front panel of th

Strany 34

Safety Information This Eutech Instruments Controller/ Transmitter shall be installed and operated only in the manner specified in the Instruction m

Strany 35 - HOLD HOLD HOLD

Instruction Manual αlpha CON 2000 347.2 Manual relay mode In manual relay mode, you can manually turn “on” and “off” the control devices connec

Strany 36

Instruction Manual αlpha CON 2000 358 TECHNICAL SPECIFICATIONS 8.1 General specifications Conductivity Measuring range No Measuring range

Strany 37

Instruction Manual αlpha CON 2000 36Alarm Functions Function (switchable) Latching / pulse Pickup delay 0 to 2000 seconds Switching voltage M

Strany 38

Instruction Manual αlpha CON 2000 37 Mechanical Specifications Dimensions 144 x 144 x 111.5 mm (5.67 x 5.67 x 4.39 inch) Weight 950 g Material

Strany 39 - 7 RELAY MODES

Instruction Manual αlpha CON 2000 389 ACCESSORIES 9.1 Replacement Unit Product Description Eutech Instruments Order Code αlpha CON 2000 Contr

Strany 40 - 7.2 Manual relay mode

Instruction Manual αlpha CON 2000 3910 GENERAL INFORMATION 10.1 Warranty Eutech Instruments supplies this product with a warranty of one year

Strany 41 - 8 TECHNICAL SPECIFICATIONS

Instruction Manual αlpha CON 2000 4010.5 Maintenance and Cleaning Maintenance The αlpha CON 2000 contains no user repairable components. P

Strany 42

Instruction Manual αlpha CON 2000 4111 APPENDICES 11.1 Appendix 1 – Unit fuse and jumper settings Caution! Before opening the unit to replac

Strany 43

Instruction Manual αlpha CON 2000 42Panel mounting version (view from top)

Strany 44 - 9 ACCESSORIES

Instruction Manual αlpha CON 2000 4311.2 Appendix 2 – Conductivity of various aqueous solutions at 25 °C / 77 °F Conductivity Resistivity Ult

Strany 45 - 10 GENERAL INFORMATION

TABLE OF CONTENTS 1 INTRODUCTION...

Strany 46

Instruction Manual αlpha CON 2000 4411.3 Appendix 3 – Simple explanation on the function of hysteresis 100 120 1880 1900RELAY OFFHYSTERESIS BA

Strany 47 - 11 APPENDICES

Instruction Manual αlpha CON 2000 4511.4 Appendix 4 – General instructions concerning Controller Setting 11.4.1 Control characteristic of Cont

Strany 48

Instruction Manual αlpha CON 2000 46 11.4.4 Control signal of Pulse length Controllers RelayONtONtOFFPulse Length TOFFTime [s] The output r

Strany 49

Instruction Manual αlpha CON 2000 47 11.4.5 Control signal of Pulse Frequency Controllers RelayONtONtOFFPulse Length TOFFTime [s] The outpu

Strany 50 - 100 120 1880 1900

Instruction Manual αlpha CON 2000 4811.5 Appendix 5 – Abbreviations used in menu displays Abbreviation Meaning Abbreviation Meaning MEAS Meas

Strany 52

For more information on Eutech Instruments’ products, contact your nearest distributor or visit our website listed below:

Strany 53

10.2 PACKAGING / SCOPE OF DELIVERY... 39 10.3 RET

Strany 54

Instruction Manual αlpha CON 2000 11 INTRODUCTION 1.1 At the very beginning We thank you for having purchased the Eutech Instruments αlpha CO

Strany 55

Instruction Manual αlpha CON 2000 21.3 Safety intsructions The αlpha CON 2000 should be installed and operated only by personnel familiar with

Strany 56

Instruction Manual αlpha CON 2000 32 PRODUCT DESCRIPTION 2.1 Description of unit The Eutech Instruments αlpha CON 2000 is used for measuring