Instruction Manual
CyberScan PC 10
Hand-held pH/Conductivity/Temperature Meter
&
Waterproof Hand-held pH/Conductivity/Temperature Meter
68X230401 rev 2
03/2002
Postbus 50, 2760 AB Zevenhuizen, Nederland
Tel: 0180 – 631344 Fax: 0180 - 632917
E-mail: [email protected] http://www.tqcinfo.nl
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - Instruction Manual

TechnologyMadeEasy...Instruction Manual CyberScan PC 10 Hand-held pH/Conductivity/Temperature Meter &Waterproof Hand-held pH/Conductivity/Temperat

Strany 2

63.2 Connecting the probe The Eutech Instruments Standard/Waterproof PC 10 meter uses a specialty combination pH / Conductivity / Temperature probe.

Strany 3 - TABLE OF CONTENTS

73.3. Connecting the AC Adapter (only for Standard PC10 meter) The AC adapter is not included with your meter; order separately. See the “Accessories

Strany 4

84. CALIBRATION 4.1. Important Information on Meter Calibration When you recalibrate your meter, old pH and conductivity calibration data are repla

Strany 5 - 1. INTRODUCTION

94.2. Preparing the Meter for Calibration The pH/conductivity/temperature probe included with this meter is designed for use with this meter only.

Strany 6 - CONMEAS CAL

103. Dip the probe into the calibration buffer. The end of the probe must be completely immersed into the sample. Stir the probe gently to create a

Strany 7 - 2.2. Keypad

117. Press the V or W key to select the next buffer value you want to calibrate (pH 4.00, 7.00 or 10.00).See Figure 12. 8. Rinse the probe with de-io

Strany 8 - 3. PREPARATION

124.4. Conductivity Calibration Ideally, you should select a conductivity standard with a value near the sample value you are measuring. The next be

Strany 9

13Calibrating for Conductivity: 1. Pour out two separate portions of your calibration standard and one of deionized water into separate clean contain

Strany 10 - 3.2 Connecting the probe

148. Press the ENTER key to confirm calibration. Upon confirmation, the CON indicator appears briefly. The meter automatically switches back into M

Strany 11

154.5. Temperature Calibration The built-in temperature sensor included in the probe is factory calibrated. Calibrate your sensor only if you suspec

Strany 12 - 4. CALIBRATION

PrefaceThis manual serves to explain the use of the Standard CyberScan PC 10 and Waterproof CyberScan PC 10 hand-held meters. It functions in two way

Strany 13 - 4.3. pH Calibration

166. Press the ENTER key to confirm temperature calibration. The CON indicator will flash to confirm calibration.See Figure 20. NOTESTo exit from T

Strany 14

175. MEASUREMENT The READY indicator appears on the display when the readings stabilize. It will turn off if the readings start to fluctuate. NOTE:

Strany 15

186. HOLD FUNCTION This feature lets you freeze the value of the pH or conductivity reading for a delayed observation. HOLD can be used any time when

Strany 16

197. PROBE CARE AND MAINTENANCE Under typical operating conditions, the probe will need to be replaced every 6 to 12 months. In extreme applications

Strany 17 - Figure 14- Calibration mode

208. TROUBLESHOOTING Problem Cause Solution Press ON key but no display 1. Batteries not in place. 2. Batteries not in correct polarity (+ and -).

Strany 18

219. ERROR MESSAGES LCD Display Indicates Cause Solution Err annunciator Unrecognized input from keypad Wrong input in selected mode.Release key.

Strany 19

2210. SPECIFICATIONS Mode Ph Temperature Conductivity Range 0.00 to 14.00 pH 0.0 to 100.0 °C 0 to 19.99 µS 0 to 199.9 µS 0 to 1999 µS 0 to 19.99 mS

Strany 20

2311. ACCESSORIES Replacement Meter and Meter accessoriesOrdering Code No. Item EC-PHCON-10 CyberScan PC 10 Hand-held pH & Conductivity meter w

Strany 21 - 5. MEASUREMENT

24Calibration SolutionsOrdering Code No. Item EC-PHSTR Storage solution for pH/Conductivity probe (EC-COMBI03M) EC-BU-4BT pH 4.01 buffer solution,

Strany 22 - 6. HOLD FUNCTION

2512. WARRANTY Eutech Instruments warrants this meter to be free from significant deviations in material and workmanship for a period of three years.

Strany 23

TABLE OF CONTENTS 1. INTRODUCTION... 12. DISPLAY AND KEYPAD FUNC

Strany 24 - 8. TROUBLESHOOTING

2613. RETURN OF ITEMS Authorization must be obtained from our Customer Service Department or authorized distributor before returning items for any rea

Strany 26 - 10. SPECIFICATIONS

11. INTRODUCTION Thank you for selecting Eutech Instruments portable meter. The Eutech Standard/Waterproof PC 10 portable meter is a microprocessor-b

Strany 27 - 11. ACCESSORIES

22. DISPLAY AND KEYPAD FUNCTIONS 2.1. Display The LCD has a primary and secondary display. x The primary display shows the measured pH or conductiv

Strany 28 - Calibration Solutions

32.2. Keypad The large membrane keypad makes the instrument easy to use. Each button, when pressed, has a corresponding graphic indicator on the LCD.

Strany 29 - 12. WARRANTY

43. PREPARATION 3.1.1 Inserting the Batteries (Standard CyberScan PC 10) The CyberScan is packaged with 4 “AAA” alkaline batteries required for opera

Strany 30 - 13. RETURN OF ITEMS

53.1.2 Inserting the Batteries (Waterproof CyberScan PC 10) Four AAA batteries are included with your meter. 1. Use a Philips screwdriver to remo