Instruction Manual DO 110 Hand-held Dissolved Oxygen Meter with RS 232C TechnologyMadeEasy...68X361305 Rev. 0 - 11/05

Strany 2

Instruction Manual CyberScan DO 110 5NOTE: Do not substitute other probes or electrodes. For replacement probe, see the “Accessories” section.

Strany 3 - Rev. 0 - 11/05

Instruction Manual CyberScan DO 110 63.3 Connecting the AC/DC Adapter Besides using four AAA-sized batteries as a power source, the DO 110 met

Strany 4 - TABLE OF CONTENTS

Instruction Manual CyberScan DO 110 7 3.4.1 RS232C Configuration The DO 110 meter has a 9 pin female RS232C connector with the following pin o

Strany 5

Instruction Manual CyberScan DO 110 84 CALIBRATION 4.1 Important Information on Meter Calibration The amount of oxygen dissolved in water wi

Strany 6 - 1 INTRODUCTION

Instruction Manual CyberScan DO 110 94.2 Temperature Calibration DO in mg/L is dependent on temperature, so it is first necessary to calibrate

Strany 7 - -1.8.8.8

Instruction Manual CyberScan DO 110 104.3 DO Calibration (with ATC) –% Saturation Mode Dissolved Oxygen exact calibration value depends on bar

Strany 8 - 2.2 Keypad

Instruction Manual CyberScan DO 110 114.4 DO Calibration in mg/L (ppm) Mode The amount of oxygen dissolved in a liquid will depend on its temp

Strany 9 - MADE IN S'PORE

Instruction Manual CyberScan DO 110 125 MEASUREMENT During measurement, care must be taken not to allow the membrane of the DO probe touch any

Strany 10

Instruction Manual CyberScan DO 110 135.3 Taking Measurements 1. Rinse the probe with deionised or distilled water before use to remove any i

Strany 11 - Connecting the RS232C Cable

Instruction Manual CyberScan DO 110 146 MEMORY FUNCTION The DO 110 meter can store up to 100 sets of data. You can store data in any combinatio

Strany 13 - 4 CALIBRATION

Instruction Manual CyberScan DO 110 157 PRINT FUNCTION The DO 110 meter is equipped with an RS232 communication port and a PRINT () key that f

Strany 14 - Temperature Calibration

Instruction Manual CyberScan DO 110 167.2 Sending Data To Computer or Printer When the PRINT key is pressed, there are two options: • dAt /

Strany 15

Instruction Manual CyberScan DO 110 177.2.1 Print Current Data Manually To manually print any data that is currently being measured: 1. From

Strany 16

Instruction Manual CyberScan DO 110 187.3 Print Data from Stored Memory The DO 110 meter can print data that is stored in the memory. You can

Strany 17 - 5 MEASUREMENT

Instruction Manual CyberScan DO 110 19To Print Selected Stored Data: 1. From measurement mode, press MR/▼ key. 2. “MEM” indicator appears a

Strany 18 - Taking Measurements

Instruction Manual CyberScan DO 110 208 ADVANCED SETUP FUNCTIONS The advanced setup mode lets you customize your meter to suit your preference.

Strany 19 - 6 MEMORY FUNCTION

Instruction Manual CyberScan DO 110 21 8.1 Advanced SETUP Mode Overview Press the SETUP key to enter Setup mode. Press the MI/▲ and MR/▼ keys

Strany 20 - 7 PRINT FUNCTION

Instruction Manual CyberScan DO 110 22 SETUP p 7.0 P7.0: Dissolved Oxygen Parameter P7.0 Select Barometric Pressure unit Set Ba

Strany 21 - From measurement mode

Instruction Manual CyberScan DO 110 238.2 P1.0 : Unit Configuration (COF) This subgroup program allows customising the meter to your specific

Strany 22 - Flash for 0.5 seconds

Instruction Manual CyberScan DO 110 248.2.2 P1.2: Select °C or °F temperature units The DO 110 meter lets you select between °C and °F units f

Strany 23

Preface This manual serves to explain the use of the hand-held series meters. The model covered is the DO 110 hand-held meter. The manual functions i

Strany 24 - Repeat print procedure or

Instruction Manual CyberScan DO 110 25measurement mode. 8.2.4 P1.4: Select mg/L or ppm mode (Only in mg/L (ppm) Set Up mode) From the mg/L

Strany 25 - 8 ADVANCED SETUP FUNCTIONS

Instruction Manual CyberScan DO 110 268.3 P2.0: Viewing Previous Calibration Data (CAL) This mode lets you recall previous calibration data,

Strany 26 - Advanced SETUP Mode Overview

Instruction Manual CyberScan DO 110 278.4.2 EL.2 Viewing the % Saturation Offset (Only available in % Saturation Set Up menu): This parameter

Strany 27

Instruction Manual CyberScan DO 110 288.5 P4.0 : Auto-Off (AtO) In Program P4.0 you can activate the AUTO-OFF option to automatically power of

Strany 28 - READY ON, OFF or HOLD

Instruction Manual CyberScan DO 110 298.6 P5.0 : Reset to Factory Default (rSt) This mode lets you reset all parameters to factory default set

Strany 29

Instruction Manual CyberScan DO 110 308.6.2 User Reset This program clears all data including calibration, memory and other customised setup f

Strany 30

Instruction Manual CyberScan DO 110 318.7 P 6.0: Memory Clear (CLr) Use this parameter to clear all memory values when you need to store a ne

Strany 31

Instruction Manual CyberScan DO 110 328.8 P7.0: Dissolved Oxygen Parameters (DPr) This Set Up menu allows you to set the barometric pressure a

Strany 32 - Set Up menu):

Instruction Manual CyberScan DO 110 338.9 P 8.0: % Saturation Offset Adjustment (OFS) This is a useful feature that allows you to offset meter

Strany 33 - P4.0 : Auto-Off (AtO)

Instruction Manual CyberScan DO 110 349 CYBERCOMM PORTABLE DAS The DAS software is designed for pH 110, CON 110 and DO 110 meters to allow you

Strany 34

TABLE OF CONTENTS 1 INTRODUCTION ... 1 2 DISPLAY &a

Strany 35 - 8.6.2 User Reset

Instruction Manual CyberScan DO 110 35 Figure 26: Click on 'Browse' button and locate CD-ROM drive Figure 27: Locate the CyberComm

Strany 36 - Figure 24: P6.0 - Clear

Instruction Manual CyberScan DO 110 36 Figure 28: Select ‘Portable Meters’ directory to go to CyberComm Portable. Figure 29: Open ‘CyberComm

Strany 37

Instruction Manual CyberScan DO 110 37 Figure 30: Select "SETUP.EXE" program and click the OPEN button Figure 31: InstallShield Wiz

Strany 38

Instruction Manual CyberScan DO 110 38 Figure 33: Key in your name and company name and click NEXT button Figure 34: To select another Dest

Strany 39 - 9 CYBERCOMM PORTABLE DAS

Instruction Manual CyberScan DO 110 39 Figure 35: Creating a new program folder. Click on NEXT button. Figure 36: Click on NEXT button.

Strany 40

Instruction Manual CyberScan DO 110 40 Figure 37: The CyberComm Portable DAS program is fully installed. Click on FINISH button to end installa

Strany 41

Instruction Manual CyberScan DO 110 419.3 Running CyberComm Portable Before running the DAS program, please ensure that the RS232 cable is con

Strany 42

Instruction Manual CyberScan DO 110 42i. Buttons & Check-Box • Enable Connection - Click this button to enable communication between mete

Strany 43

Instruction Manual CyberScan DO 110 43 Figure 41: Communication Settings for computer's Com port. It must match with COM port settings on

Strany 44

Instruction Manual CyberScan DO 110 44 9.4 Capturing And Printing Data Into Computer Using Data Acquisition After matching the Communication

Strany 45

8.6.2 User Reset ... 30 8.7 P 6.0:

Strany 46 - Running CyberComm Portable

Instruction Manual CyberScan DO 110 4510 Dissolved Oxygen Probe 10.1 Dissolved Oxygen Principle The probe is a galvanic measuring element whi

Strany 47

Instruction Manual CyberScan DO 110 4610.3 Membrane Housing Replacement Replacement of the membrane cap housing/ membrane is required only whe

Strany 48

Instruction Manual CyberScan DO 110 47Figure 35: Use Tool to take out (or put in) membrane 10.4 Membrane/O-ring Replacement (Optional Procedur

Strany 49 - Trouble-shooting Guide

Instruction Manual CyberScan DO 110 4814. Replace probe guard. 15. Calibrate the probe (see section 4) after the % saturation readings have

Strany 50 - 10 Dissolved Oxygen Probe

Instruction Manual CyberScan DO 110 4911 ERROR MESSAGES The following table provides a guideline to enable diagnosis of possible problems ind

Strany 51 - Membrane Housing Replacement

Instruction Manual CyberScan DO 110 50then there is probably moisture somewhere. See Problem 2. With membrane cap removed and probe internals

Strany 52

Instruction Manual CyberScan DO 110 5113 LIST OF ACCESSORIES 13.1 Replacement Meter and Meter accessories Eutech Instruments Items Order Cod

Strany 53 - Electrolyte Solution

Instruction Manual CyberScan DO 110 5214 SPECIFICATIONS Dissolved Oxygen Range Resolution Relative accuracy 0.00 – 19.99 mg/L or ppm 0.01 m

Strany 54 - 12 TROUBLE-SHOOTING

Instruction Manual CyberScan DO 110 5315 WARRANTY This meter is supplied with a three-year warranty, six-month warranty for probe against signi

Strany 56 - 13 LIST OF ACCESSORIES

Instruction Manual CyberScan DO 110 11 INTRODUCTION Thank you for selecting the DO 110 meter. These meters are microprocessor-based instruments

Strany 57 - 14 SPECIFICATIONS

For more information on Eutech Instruments/ Oakton Instruments’ products, contact your nearest distributor or visit our website

Strany 58 - 16 RETURN OF ITEMS

Instruction Manual CyberScan DO 110 22 DISPLAY & KEYPAD FUNCTIONS 2.1 Display The LCD has a primary and secondary display. • The primary

Strany 59

Instruction Manual CyberScan DO 110 32.2 Keypad A large membrane keypad makes the instrument easy to use. Some buttons have several function

Strany 60

Instruction Manual CyberScan DO 110 43 PREPARATION 3.1 Inserting the Batteries This meter is packaged with 4 “AAA” alkaline batteries required