TechnologyMadeEasy... Instruction Manual PC 10 Waterproof Hand-held pH/Conductivity/Temperature Meter 68X230401 Rev 5 08/04

Strany 2

Instruction Manual PC 10 - 6 - 4. CALIBRATION 4.1. Important Information on Meter Calibration When you recalibrate your meter, old pH and conducti

Strany 3 - Rev 5, 08/04

Instruction Manual PC 10 - 7 - 4.2. Preparing the Meter for Calibration The pH/conductivity/temperature probe included with this meter is designed

Strany 4

Instruction Manual PC 10 - 8 - 4.3. Temperature Calibration The built-in temperature sensor included in the probe is factory calibrated. Calibrate

Strany 5 - 1. INTRODUCTION

Instruction Manual PC 10 - 9 - 6. Press the ENTER key to confirm temperature calibration. The CON indicator will flash to confirm calibration. See

Strany 6 - CONMEAS CAL

Instruction Manual PC 10 - 10 - 4.4. pH Calibration This instrument is capable of up to 3-point pH calibration to ensure accuracy across the entire

Strany 7 - 2.2. Keypad

Instruction Manual PC 10 - 11 - 6. After the reading has stabilized and the READY indicator is displayed, press ENTER to confirm calibration. A co

Strany 8 - 3. PREPARATION

Instruction Manual PC 10 - 12 - 4.5. Conductivity Calibration The Important Information on Conductivity Calibration Your meter has four measuring ra

Strany 9 - 3.2 Connecting the Probe

Instruction Manual PC 10 - 13 - 4.6. Calibrating for Conductivity: 1. Pour out two separate portions of your calibration standard and one of DI wat

Strany 10 - 4. CALIBRATION

Instruction Manual PC 10 - 14 - 6. Press the ENTER key to confirm calibration. Upon confirmation, the CON indicator appears briefly. The meter auto

Strany 11 - Instruction Manual PC 10

Instruction Manual PC 10 - 15 - 5. MEASUREMENT The READY indicator appears on the display when the readings stabilise. It will turn off if the readi

Strany 13

Instruction Manual PC 10 - 16 - 6. HOLD FUNCTION This feature lets you freeze the value of the pH or conductivity reading for a delayed observation.

Strany 14 -  or  key to scroll up or

Instruction Manual PC 10 - 17 - 7. PROBE CARE AND MAINTENANCE Under typical operating conditions, the probe will need to be replaced every 6 to 12 m

Strany 15

Instruction Manual PC 10 - 18 - 8. TROUBLESHOOTING Problem Cause Solution No display when turned on 1. Batteries not in place. 2. Batteries not i

Strany 16

Instruction Manual PC 10 - 19 - 9. ERROR MESSAGES LCD Display Indicates Cause Solution Err annunciator Unrecognised input from keypad Wrong inpu

Strany 17 - Figure 16: CAL Indicator

Instruction Manual PC 10 - 20 - 10. SPECIFICATIONS Mode pH Temperature Conductivity Range 0.00 to 14.00 pH 0.0 to 100.0 °C 0 to 19.99 µS 0 to 199

Strany 18

Instruction Manual PC 10 - 21 - 11. ACCESSORIES 11.1. Replacement Meter and Meter accessories Eutech Instruments Item Ordering Code Waterproof PC 1

Strany 19 - 5. MEASUREMENT

Instruction Manual PC 10 - 22 - Oakton Instruments Item Ordering Code Waterproof PC 10 pH / Conductivity / Temperature meter and electrode (EC-COM

Strany 20 - 6. HOLD FUNCTION

Instruction Manual PC 10 - 23 - 11.2. Calibration Solutions Note: pH buffer solutions have ±0.01 pH accuracy at 25 °C. Conductivity standard solut

Strany 21

Instruction Manual PC 10 - 24 - 12. WARRANTY This meter is supplied with a three -year warranty, six-month warranty for probe against significant dev

Strany 22 - 8. TROUBLESHOOTING

Instruction Manual PC 10 - 25 - 13. RETURN OF ITEMS Authorisation must be obtained from our Customer Service Department or authorised distributor bef

Strany 23 - 9. ERROR MESSAGES

Preface This manual serves to explain the use of the Waterproof PC 10 hand-held meters. It functions as a step by step guide to help you operate the

Strany 25 - 11. ACCESSORIES

For more information on Eutech Instruments/ Oakton Instruments’ products, contact your nearest distributor or visit our website

Strany 26 - Oakton Instruments

TABLE OF CONTENTS 1. INTRODUCTION ...1 2. DISPLAY AND KEYPAD FU

Strany 27 - 11.2. Calibration Solutions

Instruction Manual PC 10 - 1 - 1. INTRODUCTION Thank you for selecting the Waterproof PC 10 portable meter. The meter is a microprocessor-based inst

Strany 28 - 12. WARRANTY

Instruction Manual PC 10 - 2 - 2. DISPLAY AND KEYPAD FUNCTIONS 2.1. Display The LCD has a primary and secondary display. • The primary display sho

Strany 29 - 13. RETURN OF ITEMS

Instruction Manual PC 10 - 3 - 2.2. Keypad The large membrane keypad makes the instrument easy to use. Each button, when pressed, has a corresponding

Strany 30

Instruction Manual PC 10 - 4 - 3. PREPARATION 3.1 Inserting the Batteries The meter is packaged with 4 “AAA” alkaline batteries required for operat

Strany 31

Instruction Manual PC 10 - 5 - 3.2 Connecting the Probe The Waterproof PC 10 meter uses a special combination pH / Conductivity / Temperature probe.